Opensprinkler - May 17, 2019 · Step 2: Attach OpenSprinkler to the wall, and re-inser t the wires: Refer to the Hardware Interface diagram and Zone Wire Connection diagrams on the previous pages. All terminal blocks on OpenSprinkler can be unplugged for easy wiring. To unplug, firmly grab both ends of the terminal block, wiggle, and pull it out.

 
 OpenSprinkler is an open-source web-based sprinkler controller / irrigation timer built upon open-source hardware and software. It works with standard 24V AC sprinkler valves commonly found in household watering and irrigation systems. You may be planning to buy a conventional sprinkler timer, but chances are that these systems provide a ... . Yupp

So in case you are looking for a 24V AC relay to work with OpenSprinkler in order to switch high-voltage devices, this is an inexpensive (. 2. Schrack RT314524: This is a very small 24V AC relay that you can buy from Mouser or Digikey. It has a contact rating of 16A @ 250VAC, which is also plenty for common applications.Jun 6, 2019 · In the settings popup, click the Advanced tab and select “GPIO” as the station type. You can now select the gpio pin that you want to toggle when this station needs to water. Make sure you then wire up that gpio pin to the corresponding relay. You may need to swap the Active High/Low setting in the Advanced options depending on your ...May 18, 2019 · I’m fairly new to OpenSprinkler, but I do like it very much. I’ve installed it on a Raspi and connected and set up a relay board to play a little with some valves (24V AC). Right now I’m testing the weather integration and the Zimmermann method. I think I understood the calculations in the method but I’ve a hard time finding out why it ...Jun 12, 2020 · The weather algorithm is just an algorithm, it’s not human intelligence, it can’t read your mind. That’s why you are given parameters which you can tweak to fit your own specific need. You can’t expect it to work perfectly with the default settings. I think your expectation is too high.The time is calculated using two pieces of information: the NTP time (which is UTC+0 time) and the time zone (this is obtained from the opensprinkler weather server, which calculates your time zone using your location). If you export your configurations to a .json file, and open the file, there is a variable called “tz”, which is the time zone.OpenSprinkler › Forums › OpenSprinkler Unified Firmware › Unable to load UI This topic has 16 replies, 5 voices, and was last updated 9 years, 6 months ago by Ray . Viewing 17 posts - 1 through 17 (of 17 total)Once we have the code, we can use OpenSprinkler to simulate the code, thus be able to control remote devices. Heads-up: the following steps require a small amount of soldering. The estimate time for modification is 15 to 20 minutes. Step 1: Decode Remote Power Sockets. Take out the RFToy, plug in a 433MHz receiver (making sure the VCC and …Nov 11, 2017 · Thanks! November 30, 2017 at 10:39 pm #48410. Ray. Keymaster. Not yet. Have been working on integrating Jeff Lawrence’s improved OpenGarage firmware, which does integrate MQTT for OpenGarage, and the same feature can be integrated into OpenSprinkler. I’ve put it on todo list now. April 3, 2018 at 1:35 pm #49483. OpenSprinkler Station is for gaining advanced controls and status information over a single station (zone) of a device, e.g. to turn it on or off, or the time remaining. OpenSprinkler Device is for device-specific controls that usually apply to multiple stations or main unit sensors, e.g. if rain was detected.Use SSVNC on the client and TightVNC on the pi to access the pi’s desktop through the SSH tunnel. Run the interval program via Chromium web browser on the pi’s desktop. It took a little setup but it works smoothly. Maybe someday the ospi code will be secured. April 3, 2014 at 4:59 am #26340.For OpenSprinkler 3.x only — one major step forward is the support of OpenThings Cloud (OTC) token, which allows remote access via the OTC cloud server. This eliminates the need for settings up port forwarding, which has been a pain for manual users. OTC has been enabled for our OpenGarage product for a while, and it seems to …Question about “NEW from OpenSprinkler v3.2: from v3.2, the controller has dual support for WiFi and wired Ethernet.” which as far as I can see is related to 2.2.0(1)s update to ESP8266 WiFi Core 3.0.2 and lwip as wired Ethernet library. I’m using ethernet. After upgrading firmware I’m seeing the AP mode running even when the …ESPToy v2. $ 12.99 9.99. ESPToy is a WiFi development board for ESP8266. Version 2.0 has on-board Neopixel color LED, mini buzzer, button, light sensor, LiPo battery jack and charging chip. It has built-in CH340 USB-serial and auto-reset circuit. It’s pre-flashed with a demo software written in Arduino with ESP8266 core.Aug 25, 2013 · OpenSprinkler Pi is an extension board for Raspberry Pi (RPi) (all versions of RPi). It allows RPi to directly access and control sprinkler valves. NOTE: OSPi no longer comes with enclosure. Instead, the design of a 3D printable enclosure is provided, you can use it to print the enclosure yourself, or order it online, such as from jlcpcb.com. Keymaster. 1. yes, it should work with OpenSprinkler. The output of this soil clik sensor is a relay which is a dry contact type. 2. no, this soil sensor is not a dry contact type, it requires an additional microcontroller to ‘interpret’ the result of the soil moisture value. It cannot be used directly with OpenSprinkler. OpenSprinkler owners can use this solution to send their PWS weather observations onto a local Weather Service server. For more information on the "WeeWX Solution" click here. 4 ) Solutions for specific PWS (provided by OpenSprinkler Forum members) Davis Vantage: a solution for this PWS has been kindly provided by @rmloeb hereJun 6, 2019 · In the settings popup, click the Advanced tab and select “GPIO” as the station type. You can now select the gpio pin that you want to toggle when this station needs to water. Make sure you then wire up that gpio pin to the corresponding relay. You may need to swap the Active High/Low setting in the Advanced options depending on your ...Regarding concurrent vs sequential running modes, currently the only option is to globally switch between the two (i.e. either all stations run sequentially, or all stations are allowed to run concurrently). There is currently no support for subsets of sequential groups. July 5, 2013 at 7:43 pm #24613. djMax.24VAC/500mA sprinkler transformer for OpenSprinkler AC and OpenSprinkler Pi. Please note that this plug is only for 110~120v U.S. outlets. Due to the low current rating (500mA), it is NOT suitable to run more than 2 valves at the same time (i.e. concurrent/simultaneous zones). If you need to run more zones at the same time, please find a 24VAC …Participant. If by “run 2 valves at the same time”, you mean run 2 stations/zones at the same time, then yes, you can. The stations that you want to run in parallel must have the sequential attribute set to off. You do not need a separate program, but you may have other considerations when you create programs that have a mix of … OpenSprinkler User Manual F i r m w are 2. 1. 8 ( May 31, 2018) C o n t e n t s I n t ro d u c t i o n H a rd w a re I n t e r f a c e Mar 25, 2021 · Part 2: Add OpenSprinkler Integration. Navigate to Configuration > Integrations > Add Integration. Search for OpenSprinkler. Next, add your OpenSprinkler IP address, login password, and controller name. MAC address can be left blank. Then, click Submit. Assign it to an area like your garage and click Finish. OpenSprinkler › Forums › OpenSprinkler Mobile and Web App. This forum has 347 topics, 2,144 replies, and was last updated 1 day, 6 hours ago by Ray. Viewing 26 topics - 1 through 25 (of 347 total) 1 2 3 ... OpenSprinkler User Manual F i r m w are 2. 1. 8 ( May 31, 2018) C o n t e n t s I n t ro d u c t i o n H a rd w a re I n t e r f a c e OpenSprinkler › Forums › OpenSprinkler Mobile and Web App › Changing the user interface This topic has 17 replies, 5 voices, and was last updated 7 years, 8 months ago by 951calguy . Viewing 18 posts - 1 through 18 (of 18 total)The application allows you to automatically detect and control your OpenSprinkler irrigation system(s). OpenSprinkler is an open-source Internet web … OpenSprinkler Zone Expander. $ 49.00 – $ 50.00. OpenSprinkler Zone Expander provides an easy and inexpensive way to increase the number of stations for your OpenSprinkler. Each expander adds 16 zones. Please note that there is NO expander for OpenSprinkler Latch — the DC expander will NOT work with OpenSprinkler Latch. Its simple, after speaking with DAB , the pump regulates pressure in the line as the solenoids are opened by open sprinkler controller than pushes water to the desired zone. Once the zone solenoid turns off the water pressure in the line signals the pump to turn off. There is a delay of 10 sec which is standard from the manufacture and can be ...Jan 6, 2021 · Hello, I have created a HW/SW variant from OpenSprinkler based on the ESP32-WROOM module and including a Lora SX1262 module (long range). This variant allows a device to be configured as master (remote) or slave (station). Any action in the remote will be transmitted to the station over the MirrorLink lora protocol.Rain gauge is currently not supported: at least not supported if you want to use it to stop watering when a certain amount of rain is received. Technically rain gauge works like a flow sensor — the reed switch internally turns on and off repeatedly to indicate the rate at which rain is accumulated. You can use rain gauge in the sense that you ...Mar 24, 2021 · Unscrew each of them first. Insert each wire and tighten them down with a small screwdriver. The red zone cables should be inserted into the corresponding zones (Zone 1 on the old system goes into #1 on OpenSprinkler). The black P/MV cable is your pump/master valve. Plug this into an available zone (either 7 or 8). 24VAC/500mA sprinkler transformer for OpenSprinkler AC and OpenSprinkler Pi. Please note that this plug is only for 110~120v U.S. outlets. Due to the low current rating (500mA), it is NOT suitable to run more than 2 valves at the same time (i.e. concurrent/simultaneous zones). If you need to run more zones at the same time, please find a 24VAC …OpenSprinkler owners can use this solution to send their PWS weather observations onto a local Weather Service server. For more information on the "WeeWX Solution" click here. 4 ) Solutions for specific PWS (provided by OpenSprinkler Forum members) Davis Vantage: a solution for this PWS has been kindly provided by @rmloeb hereThis is an ESP32 port of OpenSprinkler 2.1.9 firmware. As ESP32 has many GPIO pins, the main stations (8) are handled by ESP32 instead of any PCF8574's. All buttons are managed by the main ESP32 board too. Firmware is tested and works as AC version (DC and LA require a dedicated HW eg. voltage buster). As I do not have an ethernet board, …Thanks in advance. Cheers. Tom. March 20, 2016 at 10:18 pm #41807. Ray. Keymaster. Yes, you will need a pump start relay (because a station on OpenSprinkler DC can only drive a load up to 1 amp max, if your pump requires 5 amp, you will need a relay). March 20, 2016 at 11:09 pm #41818. tom.farmer0.24VAC/500mA sprinkler transformer for OpenSprinkler AC and OpenSprinkler Pi. Please note that this plug is only for 110~120v U.S. outlets. Due to the low current rating (500mA), it is NOT suitable to run more than 2 valves at the same time (i.e. concurrent/simultaneous zones). If you need to run more zones at the same time, please find a 24VAC …Announcing OpenSprinkler Firmware 2.2.0(1) December 30, 2022 Announcing OpenGarage Firmware 1.2.0 October 7, 2022 Learning Electronics — I/O expander options October 10, 2021Use SSVNC on the client and TightVNC on the pi to access the pi’s desktop through the SSH tunnel. Run the interval program via Chromium web browser on the pi’s desktop. It took a little setup but it works smoothly. Maybe someday the ospi code will be secured. April 3, 2014 at 4:59 am #26340.The first thing to check is at the homepage, swipe left to right (or click the upper-left corner icon) to open the left-side menu, then ‘System Diagnostics’. Look at two time stamps: the Last Weather Call and Last Successful Weather Call. If the Last Successful Weather Call time stamp lags behind the first one, or is simply not available ...OpenSprinkler › Forums › OpenSprinkler Unified Firmware › Unable to load UI This topic has 16 replies, 5 voices, and was last updated 9 years, 6 months ago by Ray . Viewing 17 posts - 1 through 17 (of 17 total)Use SSVNC on the client and TightVNC on the pi to access the pi’s desktop through the SSH tunnel. Run the interval program via Chromium web browser on the pi’s desktop. It took a little setup but it works smoothly. Maybe someday the ospi code will be secured. April 3, 2014 at 4:59 am #26340. Welcome to the OpenSprinkler application. This app only works with the OpenSprinkler controller which must be installed and setup on your home network. Purchase OpenSprinkler. OpenSprinkler.com Login. Scan For Device. Manually Add Device. OpenSprinkler unchains you from your sprinkler or irrigation control box, enabling you to program, run, or stop zones at any time from anywhere. Whether you are at your desktop, laptop, tablet or phone; whether you are at home, office, or traveling on the road, you can access OpenSprinkler through any modern browser; or use our free apps ... I think it would be extremely powerful to get alert via email for example when the flow sensor reads flow when no valves are on. In addition, I think it would be nice to get alerts when there is a 0 flow reading when the valves are on meaning the source water is not flowing (i.e. was mistakenly turned off). November 9, 2015 at 12:33 am #40714.Address OpenThings 5 Valley Lane Amherst, MA 01002 Email General Inquiry: [email protected] Orders: [email protected] Sales and Distribution: [email protected] Technical Support: support.opensprinkler.com NOTE: if you are seeking support for an existing product purchase from us, please submit a support ticket …September 29, 2022 at 11:14 am #74013. DWillys. Participant. I have a couple of the opensprinkler devices on my network. They’re set up to get their tcpip data via DHCP. In the interface I can’t find anywhere I can set the hostname so I can identify which device is which. I tried setting the hostname in the DHCP reservation (Option 12) but ...OpenSprinkler Station is for gaining advanced controls and status information over a single station (zone) of a device, e.g. to turn it on or off, or the time remaining. OpenSprinkler Device is for device-specific controls that usually apply to multiple stations or main unit sensors, e.g. if rain was detected.For instance, renaming Station 6 would rename 7 and 8 as well, but not 1-5. Tried the “Reset All Station Data” option and it just showed “reset” for most stations after it was done, but still the same issue with trying to rename them after. Tried restoring from a backup file I had and still had the same issues.I am interested to discuss the integration of OpenSprinkler with other software. Perhaps the first step of this process should be for the designers of OpenSprinkler to share their vision of how OpenSprinkler is to integrate with IOT. My understanding is that the python version of OpenSprinkler has MQTT support, which …November 30, 2017 at 10:39 pm #48410. Ray. Keymaster. Not yet. Have been working on integrating Jeff Lawrence’s improved OpenGarage firmware, which does integrate MQTT for OpenGarage, and the same feature can be integrated into OpenSprinkler. I’ve put it on todo list now. April 3, 2018 at 1:35 pm #49483. perscheid.Apr 28, 2014 · OpenSprinkler (Arduino-based) This is the story of how learning Arduino inspired me to invent the OpenSprinkler — an open-source, web-based sprinkler controller. I’ve had a passion for making electronic circuits since I was a kid, spending hours looking at schematics and building simple circuits like a single-transistor radio, an electronic cricket, …Open Sprinkler is a free, open source, self hosted, browser based controller for your sprinkler system, and it can run through a Raspberry Pi. It has a simp...One thing you can check is the wire resistance. Use an online calculator to compute the wire resistance, such as this one: keep in mind that you need to input the round-trip distance. Typical sprinkler valves draw about 200 to 300mA holding current, and if the voltage drops below 18V AC they are unlikely to stay on.Once we have the code, we can use OpenSprinkler to simulate the code, thus be able to control remote devices. Heads-up: the following steps require a small amount of soldering. The estimate time for modification is 15 to 20 minutes. Step 1: Decode Remote Power Sockets. Take out the RFToy, plug in a 433MHz receiver (making sure the VCC and …Announcing OpenSprinkler Firmware 2.2.0(1) December 30, 2022 Announcing OpenGarage Firmware 1.2.0 October 7, 2022 Learning Electronics — I/O expander options October 10, 2021Feb 22, 2020 · Open Sprinkler is a free, open source, self hosted, browser based controller for your sprinkler system, and it can run through a Raspberry Pi. It has a simp... OpenSprinkler unchains you from your sprinkler or irrigation control box, enabling you to program, run, or stop zones at any time from anywhere. Whether you are at your desktop, laptop, tablet or phone; whether you are at home, office, or traveling on the road, you can access OpenSprinkler through any modern browser; or use our free apps ... A quick note that our Black Friday / Cyber Monday sales are on now: all OpenSprinkler products are shown in discounted prices right now, and the deal only lasts till Monday Nov 28. This is the only time of the year that we offer discounted pricing, so if you are interested in buying OpenSprinkler, grasp this chance and don’t let it slip away ...Oct 10, 2021 · PCA9555 and PCA9535 both have 16 I/O pins, and both use Totem-poll output, so they can both sink and source a large amount of current. They are used in the current OpenSprinkler 3.2 controller and zone expanders. The only difference between the two is that PCA9555 has built-in pull-up resistor while PCA9535 does not.If you don’t fill the event name or you use the wrong event name, you won’t receive notification. – Go to your webhooks documentation link to find the IFTTT token. Then put it in OpenSprinkler settings …Mar 24, 2021 · Insert each wire and tighten them down with a small screwdriver. The red zone cables should be inserted into the corresponding zones (Zone 1 on the old system goes into #1 on OpenSprinkler). The black P/MV cable is your pump/master valve. Plug this into an available zone (either 7 or 8).Sep 22, 2019 · Hi there, got your your OpenSprinkler 2 days ago and trying to get all setup done since then. Wifi setup working perfectly. Remote access is the one I struggle with. Went through your topics about port forwarding etc. On my Netgear router, I changed the following Static Leases MAC Address Hostname IP Address Client LeaseOpenSprinkler Pi is an extension board for the Raspberry Pi. It makes use of the Raspi's GPIO pins to directly interface with sprinkler valves. It features a...Its simple, after speaking with DAB , the pump regulates pressure in the line as the solenoids are opened by open sprinkler controller than pushes water to the desired zone. Once the zone solenoid turns off the water pressure in the line signals the pump to turn off. There is a delay of 10 sec which is standard from the manufacture and can be ...September 29, 2022 at 11:14 am #74013. DWillys. Participant. I have a couple of the opensprinkler devices on my network. They’re set up to get their tcpip data via DHCP. In the interface I can’t find anywhere I can set the hostname so I can identify which device is which. I tried setting the hostname in the DHCP reservation (Option 12) but ... Keymaster. 1. yes, it should work with OpenSprinkler. The output of this soil clik sensor is a relay which is a dry contact type. 2. no, this soil sensor is not a dry contact type, it requires an additional microcontroller to ‘interpret’ the result of the soil moisture value. It cannot be used directly with OpenSprinkler. There are a bunch of kinds…. -two wire reverse polarity to open or close. -three wire, common and + to one ot open, + to the other to close. -two wire spring return – + to open, 0 to close. (more expensive but failsafe) 24vac dpdt relay driven by open sprinkler output, with a dc supply to drive the valves could be wired to any of these types.I have an old Orbit 12 zone B-Hyve sprinkler controller, but its WiFi module broke. All I had to do was to create a cable to connect the Pi Zero to the header on the power board of the Orbit. This way, the whole Orbit control module is substituted by the OpenSprinkler Pi. Please, see the wiring diagram attached as an Excel spreadsheet.Basic features of the OpenSprinkler include: - AVR Atmega328 MCU running at 8MHz, compatible with the open-source Arduino software. - Microchip ENC28J60 Ethernet controller enables web-based scheduling, through either wired Ethernet connection, or WiFi connection if used with a WiFi repeater. - Allows up to 8 water stations/zones, individually ...March 16, 2015 at 9:41 pm #36045. Ray. Keymaster. The ‘parallel stations’ are mainly intended for non-sprinkler stations — now that OpenSprinkler supports radio frequency (RF) stations (such as remote power sockets), you can use it to switch landscape lights, or other general-purpose powerline devices with OpenSprinkler.OpenSprinkler › Forums › OpenSprinkler Unified Firmware › Announcing OpenSprinkler Unified Firmware 2.1.9 (4) What's New Firmware 2.1.9 (4) is now available. The primary change in this firmware is the initial support for MQTT (thanks to the generous contributions by jbaudoux, PeteBa, and vsoltan). To use MQTT, this firmware requires … Basic features of the OpenSprinkler include: - AVR Atmega328 MCU running at 8MHz, compatible with the open-source Arduino software. - Microchip ENC28J60 Ethernet controller enables web-based scheduling, through either wired Ethernet connection, or WiFi connection if used with a WiFi repeater. - Allows up to 8 water stations/zones, individually ... According to information from Victoria Gardner, Weather Underground the gateway for obtaining keys on the new API for PWS non-commercial users is planned to open on February 15, 2019. All current WU API keys that are linked to a PWS will stay open through Friday, March 1, 2019. Links to documentation and details about data can be …Description. OpenSprinkler v3.2/3.3 wired Ethernet module, to allow wired Ethernet connection on your OpenSprinkler. Please select the correct module based on your ...Software repository for OpenSprinkler, an open-source web-based sprinkler controller. - OpenSprinklerThis way, when OpenSprinkler starts to run any program, or receives weather changes, it can send a web request to IFTTT, which further triggers a text message or push notification to your phone. Conversely, to use a Maker action, you can set IFTTT to send a web request to your gadget. This way, when it receives an associated trigger, it can ...RFToy is an Arduino-compatible gadget for interfacing with radio frequency (RF) modules. It can be used as a standalone gadget, or in conjunction with OpenSprinkler (including DC / AC / Pi) to decode and simulate RF signals on RF remote power sockets. This allows OpenSprinkler to switch not only sprinkler valves, but general devices such as lights, … Announcing OpenSprinkler Firmware 2.2.0(1) December 30, 2022 Announcing OpenGarage Firmware 1.2.0 October 7, 2022 Learning Electronics — I/O expander options October 10, 2021 NTP should be configured with /etc/ntp.conf and the ntpd daemon. NTP and static IP are options that are only available on the microcontroller-based OpenSprinkler. On OSPi (OpenSprinkler Pi), these are managed by the Linux system so they are done directly in the Linux system and not part of the firmware.Indeed it has come to my attention that the firmware had a bug that affected a small number of OpenSprinkler 2.1 units that use MCP7940 real-time clock (RTC) whereas the majority of OpenSprinkler units use DS1307 RTC. This was first discovered by a user who reported the fix in blog comments:Hi, I'm fairly new to OpenSprinkler, but I do like it very much. I've installed it on a Raspi and connected and set up a relay board to play a little with some valves (24V AC). Right now I'm testing the weather integration and the Zimmermann method. I think I understood the calculations in theHi, I'm fairly new to OpenSprinkler, but I do like it very much. I've installed it on a Raspi and connected and set up a relay board to play a little with some valves (24V AC). Right now I'm testing the weather integration and the Zimmermann method. I think I understood the calculations in theESPToy v2. $ 12.99 9.99. ESPToy is a WiFi development board for ESP8266. Version 2.0 has on-board Neopixel color LED, mini buzzer, button, light sensor, LiPo battery jack and charging chip. It has built-in CH340 USB-serial and auto-reset circuit. It’s pre-flashed with a demo software written in Arduino with ESP8266 core.This way, if the WiFi signal is lost, the remote station will not remain on for more than 2 minutes, to avoid it being left on indefinitely. As a result, if you try to read the remaining water time from the remote station, it won’t be more than 2 minutes. The exception is when the ‘special station auto-refresh’ is turned off.The OpenSprinkler web interface allows you to program water schedules and monitor station status through the web. Compared to traditional sprinkler timers, which limit you to a few buttons, dials, and a small screen, the web provides a much more intuitive user interface. You can access the controller using any device that has a built-in web ...OpenSprinkler Station is for gaining advanced controls and status information over a single station (zone) of a device, e.g. to turn it on or off, or the time remaining. OpenSprinkler Device is for device-specific controls that usually apply to multiple stations or main unit sensors, e.g. if rain was detected.Use SSVNC on the client and TightVNC on the pi to access the pi’s desktop through the SSH tunnel. Run the interval program via Chromium web browser on the pi’s desktop. It took a little setup but it works smoothly. Maybe someday the ospi code will be secured. April 3, 2014 at 4:59 am #26340.Apr 14, 2022 · Its simple, after speaking with DAB , the pump regulates pressure in the line as the solenoids are opened by open sprinkler controller than pushes water to the desired zone. Once the zone solenoid turns off the water pressure in the line signals the pump to turn off. There is a delay of 10 sec which is standard from the manufacture and can be ...

September 29, 2022 at 11:14 am #74013. DWillys. Participant. I have a couple of the opensprinkler devices on my network. They’re set up to get their tcpip data via DHCP. In the interface I can’t find anywhere I can set the hostname so I can identify which device is which. I tried setting the hostname in the DHCP reservation (Option 12) but .... Smarty smarty ants

opensprinkler

Keymaster. OpenLabs has shut down for several months and came back to business. Right now the only way for you to get OpenSprinkler is to buy directly from us (we do ship to Australia). We will be contacting OpenLabs to find out what’s their future plan. February 7, 2018 at 6:33 pm #48848.Announcements, questions, and suggestions about the OpenSprinkler Unified firmware. Questions about hardware troubles and hardware design. Explore alternative firmware solutions and software extensions developed by the community. Make comments, suggestions, or request new features. OpenSprinkler Zone Expander. $ 49.00 – $ 50.00. OpenSprinkler Zone Expander provides an easy and inexpensive way to increase the number of stations for your OpenSprinkler. Each expander adds 16 zones. Please note that there is NO expander for OpenSprinkler Latch — the DC expander will NOT work with OpenSprinkler Latch. Aug 6, 2023 · Welcome to the OpenSprinkler application. This app only works with the OpenSprinkler controller which must be installed and setup on your home network. Purchase OpenSprinkler. OpenSprinkler.com Login. Add Controller.May 16, 2020 · OpenSprinkler › Forums › Hardware Questions › Recommended flow meter This topic has 5 replies, 4 voices, and was last updated 3 years, 3 months ago by Ray . Viewing 6 posts - 1 through 6 (of 6 total) This is an ESP32 port of OpenSprinkler 2.1.9 firmware. As ESP32 has many GPIO pins, the main stations (8) are handled by ESP32 instead of any PCF8574's. All buttons are managed by the main ESP32 board too. Firmware is tested and works as AC version (DC and LA require a dedicated HW eg. voltage buster). As I do not have an ethernet board, …It adds support for OpenSprinkler hardware revision 3.3 that uses W5500 wired Ethernet module. The firmware supports both ENC28J60 and W5500 modules. It fixed a rain …1) the clock on the controller’s display is frozen at a time earlier in the day. 2) none of the 3 buttons on the controller do anything. 3) the Ethernet module’s internal red LED is still on, and the 2 LEDs on the RJ45 jack seem to reflect normal network activity. 4) the controller still responds to pings. 5) if the controller was in the ...If our distributor is out of stock, you can also buy directly from this website (https://www.opensprinkler.com) — we ship directly to most countries in the world. Products. OpenSprinkler. Rated 5.00 out of 5 $ 150.00 – $ 193.00; OpenSprinkler Bee (OSBee) Rated 4.60 out of 5 $ 62.00 – $ 72.00; OpenSprinkler Pi (OSPi)September 29, 2022 at 11:14 am #74013. DWillys. Participant. I have a couple of the opensprinkler devices on my network. They’re set up to get their tcpip data via DHCP. In the interface I can’t find anywhere I can set the hostname so I can identify which device is which. I tried setting the hostname in the DHCP reservation (Option 12) but ...Check the program’s interval time — it should not be zero. If you just want the program to run once during a day, you can use a large interval (such as 23 hours). As long as the end time minus the start time is less than the interval time, the program will run only once (at the start time). From firmware 2.1.2, the settings for each program ...Feb 22, 2020 · Open Sprinkler is a free, open source, self hosted, browser based controller for your sprinkler system, and it can run through a Raspberry Pi. It has a simp... Participant. If by “run 2 valves at the same time”, you mean run 2 stations/zones at the same time, then yes, you can. The stations that you want to run in parallel must have the sequential attribute set to off. You do not need a separate program, but you may have other considerations when you create programs that have a mix of …At 12 volts, that’s 417 ma (each). So well within the maximum OpenSprinkler spec of 800 ma per channel. But, I think the sum is too much for the 16 mil triac gnd trace on the OpenSprinkler pcb. Alternately, I could put 2:1 transformers on the OpenSprinkler channel outputs. That way I wouldn’t have to hack the OpenSprinkler pcb.To do so: Power off the controller, then power it back on. As soon as you see the word 'OpenSprinkler', press and hold the third pushbutton B3 and continue holding it until the LCD displays 'Setup Options'. Click B3 as many times as you need until you are at the 'Ignore Password' option. Click B1 or B2 to select 'Yes'.Address OpenThings 5 Valley Lane Amherst, MA 01002 Email General Inquiry: [email protected] Orders: [email protected] Sales and Distribution: [email protected] Technical Support: support.opensprinkler.com NOTE: if you are seeking support for an existing product purchase from us, please submit a support ticket ….

Popular Topics